Pump Starter with Pump-Monitor Protection Model: AP

Request Quote Request Quote
Immediate shipping on selected models, 4 to 6 days for the rest of the models.
Downloads
Download PDFDownload PDFDownload PDFDownload PDFDownload PDF
Name Download

Features

  • Protects pumps against overload, phase failure, rapid cycling, voltage failures, and low suction levels, without the need for electrodes.
  • Equipped with button station: Start, stop, or Selector: Manual-Off-Automatic.
  • Pump-Monitor is mounted on the cabinet door, allowing viewing of currents, faults, configuration, and reset without opening the cabinet.

Description

The AP Series starters are used to start and protect three-phase or single-phase pumps. They provide protection against overload, rapid cycling, and low suction levels without the need for electrodes. For three-phase pumps, they also offer phase failure protection, while for single-phase pumps, they include additional protection against low and high voltage.

This panel is ideal for installations where using electrodes is difficult, such as deep wells and where a higher level of overload protection is required.

Pump-monitor is more effective and accurate in protecting against overload than standard overload relays and has a fast phase failure protection of maximum 5 seconds.

The AP Series starters include:

Contactors, three-phase or single-phase Pump-Monitor, short-circuit protection, start-stop button station in the standard starter. Manual-Off-Automatic selector on request, operation pilot light, and transformer, mounted in a dust and water-resistant NEMA 4 (IP66) metal cabinet with corrosion-resistant paint.  

Optional Equipment

  • Manual-Off-Automatic operation selector.
  • Safety disconnect switch that cuts power when opening the cabinet.
  • Protection against low voltage, imbalance, and phase failure with Fasealert-3 model F3.
  • Soft starters.
  • Leakage detector in the seal and high-temperature model DFS-12 (1 per pump).
  • PD-640 protector against high-voltage discharges.
  • Three-phase RMS digital voltmeter with max/min voltage recording and frequency meter. Mounted on the cabinet door.
Product Information User Manual PM-22 Manual PM-23 Manual PM-31 Manual PM-32 Manual
SINGLE-PHASE
HP120 V AMP.220 V AMP.
1/44-62.5-4
1/36-102.5-4
1/26-104-6
3/413-156-10
16-10
1.59-14
29-14
313-18
524-32
7.537-50
1048-60
THREE-PHASE
HP220 V AMP.440 V AMP.
513-186-10
7.517-239-12
1024-3213-18
1537-5017-23
2048-6524-32
2563-80*30-40
3080-90*37-50
4090-115*48-65
50115-160*63-80*
6080-100*

For other capacities, please consult with us.
*Note: Soft starters are recommended for these sizes.

Related products

Pump Control Panels

Series 10: Hydropneumatic Booster Control Panel

Controls the automatic operation of 1 to 4 pumps to maintain the desired pressure in the hydropneumatic tank within the desired ranges set on the pressure switches.

Pump Control Panels

Series 10L: Digital Hydropneumatic Booster Control Panel

Tablero para sistema hidroneumático con manómetro digital y pantalla que controla la operación automática de 2 a 3 bombas para mantener la presión deseada en el tanque hidroneumático dentro de los rangos deseados ajustados por medio de la pantalla.

Pump Control Panels

Series 10V: Variable Speed Hydropneumatic Booster Control Panel

Control panel for a variable-speed hydropneumatic system that controls the automatic operation of 1 to 4 pumps to maintain the desired pressure in the hydropneumatic tank within the desired ranges set on the pressure switches. It uses 1 drive for each pump.

Pump Control Panels

Series 20: Water Recirculation Pump Control Panel

Controls the automatic alternating and simultaneous operation of recirculation pumps to maintain the desired flow based on demand.

Pump Control Panels

Series 30: Water Level Control Panel for Cistern-Tank Systems

Control panel for tank filling (water tank-cistern) that controls the automatic operation of 1 to 4 pumps, alternating and running them simultaneously to maintain the water level in the tank within the range set by the electrode level.

Pump Control Panels

Series 40: Sump and Sewage Pump Control Panel

Control panel for sump pump emptying SERIES 40 controls the automatic operation of 1 to 4 pumps, alternating and running them simultaneously to maintain the sump empty within the levels previously set with level detectors (floats).

Nassar Electronics